China Real-time icing prevention monitoring system for transmission lines - China Supplier
China Real-time icing prevention monitoring system for transmission lines - China Supplier China Real-time icing prevention monitoring system for transmission lines - China Supplier China Real-time icing prevention monitoring system for transmission lines - China Supplier China Real-time icing prevention monitoring system for transmission lines - China Supplier China Real-time icing prevention monitoring system for transmission lines - China Supplier

Real-time icing prevention monitoring system for transmission lines

Price: ¥80000
Industry Category: Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards
Product Category:
Brand: 特力康
Spec: TLKS-PMG-FB100


Contact Info
  • Add:C-9/F, Building C, Jingda Industrial Park, No. 39 Qingfeng Avenue, Longgang Street, Longgang District, Shenzhen, Zip: 518116
  • Contact: 李女士
  • Tel:13682351635
  • Email:1920671927@qq.com

Other Products

Description
Additional Information

Product Aliases: Transmission Line Ice Cover Monitoring System, Transmission Line Ice Cover Automatic Observation System, Transmission Line Ice Cover Early Warning Monitoring Device

Product Model: TLKS-PMG-FB100

Real-time Anti-icing Monitoring System for Transmission Lines




I. Product Description:

Real-time Anti-icing Monitoring System for Transmission Lines It combines image processing technology and Internet of Things (IoT) technology, and is mainly used for real-time monitoring of ice cover on transmission lines and iron towers. The built-in image processing unit processes these images, including steps such as image preprocessing, feature extraction, and status judgment. Through these technologies, the device can automatically identify and analyze ice-covered areas, accurately determine the ice cover status, so as to better carry out management and maintenance work. This greatly improves management efficiency and reduces the cost and risk of manual inspection.




II. Working Principle:

Real-time Anti-icing Monitoring System for Transmission Lines The working principle mainly includes the following steps:

1. Image Acquisition: The image information of transmission lines and iron towers is collected in real time through the installed high-definition cameras.

2. Image Processing: For the collected images, the system uses digital image processing technology for identification and analysis, including methods such as image enhancement, edge detection, and threshold segmentation, to highlight and extract ice-covered areas.

3. Feature Extraction: Based on image processing, the system further extracts feature information of ice-covered areas, such as the shape, size, location, and color of the ice cover.

4. Status Judgment: According to the extracted feature information, the system judges the status and identifies the ice cover status of transmission lines and iron towers.

5. Early Warning and Alarm: Once the ice cover status exceeds the safety threshold, the system will immediately send an early warning or alarm signal to notify management personnel to deal with it in a timely manner.

6. Data Storage and Analysis: The system also stores the monitored images and data, and conducts regular analysis to evaluate the development trend of ice cover and possible impacts.

Through the above working principles,Real-time Anti-icing Monitoring System for Transmission Lines can realize real-time monitoring of transmission lines and iron towers, detect ice cover problems in a timely manner, and take corresponding measures to ensure the safe and stable operation of the power system.




III. Product Functions:

1. It has the functions of management and self-inspection of the device's own working status, including collection, storage, processing, communication, etc.

2. When a device failure is detected, it can take corresponding measures to restore the device to normal operation.

3. It has the functions of identity authentication and remote program update, with a complete update mechanism and methods.

4. It has the ability to modify parameters such as collection frequency, sampling time interval, and network adapter address via remote commands.

5. It has the ability to dynamically respond to remote commands such as time query, data request, and reset.

6. It can enter the remote debugging mode via remote commands and output relevant debugging information.

7. It is equipped with a security chip, which can encrypt data and connect to the platforms of provincial companies.




IV. Technical Parameters:

1. Power Supply Method: Solar energy + battery

2. Communication Requirements: Supports wireless network communication, and operators can be selected according to on-site conditions.

3. Operating Voltage: DC12V

4. Standby Duration: >30 days

5. Backend Software Platform:

6. Supports access to Provincial and Municipal Bureau PMS System

7. PG Client / Mobile Client for real-time viewing of monitoring data

8. Remote update, configuration and debugging of front-end device parameters




V. Summary:

Real-time Anti-icing Monitoring System for Transmission Lines It can improve the operation efficiency and safety of the power grid, and ensure the stable operation of the power system. The device has functions such as automatic identification and analysis of ice-covered areas, early warning and alarm, and data storage and analysis, which facilitates management and maintenance work. Meanwhile, the remote monitoring function allows management personnel to access monitoring data and control equipment at any time, further improving management efficiency. In short,Real-time Anti-icing Monitoring System for Transmission Lines is an important tool to ensure the safe and stable operation of the power grid, with broad application prospects and value.

We look forward to cooperating with you to jointly explore the market and provide high-quality products and services for customers. Contact Ms. Li from Telink at: 13682351635   Landline: 0755-29500762

Customized products, the quoted price is a reference range price at the time of market release, and the actual price is subject to negotiation.







VI. Notes:

1. Avoid dropping the device on the ground or subjecting it to strong impacts from other objects.

2. Avoid strong external impacts on the solar panel to prevent damage to it.

3. When installing, try to orient the solar panel towards the sun.

4. Turn off the power switch when installing the device, and turn on the power switch after installation is complete.

5. Do not disassemble the structure or circuit board without permission; unauthorized disassembly of the device will void the warranty.

Industry Category Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards
Product Category
Brand: 特力康
Spec: TLKS-PMG-FB100
Stock: 999
Manufacturer: 深圳市特力康科技有限公司
Origin: 114403
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192
ChatGlobal TChat